{"id":6334,"date":"2026-11-20T19:44:04","date_gmt":"2026-11-20T17:44:04","guid":{"rendered":"https:\/\/inteq.lt\/ventiliatorius-elektros-spintai-oro-srautas\/"},"modified":"2026-11-20T19:45:30","modified_gmt":"2026-11-20T17:45:30","slug":"ventiliatorius-elektros-spintai-oro-srautas","status":"publish","type":"post","link":"https:\/\/inteq.lt\/en\/ventiliatorius-elektros-spintai-oro-srautas\/","title":{"rendered":"Cabinet fan for electrical enclosures: how to calculate the required airflow (m\u00b3\/h)"},"content":{"rendered":"<p>Frequency converters, power supplies, controllers and contactors give off heat. In a closed cabinet it builds up, and in summer the internal temperature can exceed what the equipment is rated for, causing faults whose cause is hard to find. A fan with a filter is the simplest solution, but it must be the right size. Here's how to calculate it.<\/p>\n<h2>Step 1. How much heat the equipment gives off<\/h2>\n<p>Add up the power losses (W) of the devices. They are listed in the manufacturers' datasheets (in English, <em>power loss, heat dissipation<\/em>). If losses are not stated, you can estimate them from the efficiency:<\/p>\n<p><strong>Losses = output power \u00f7 efficiency \u2212 output power<\/strong><\/p>\n<p>For example, a 24 V 10 A (240 W) power supply with 90% efficiency: 240 \u00f7 0.9 \u2212 240 \u2248 27 W of heat. The largest heat sources are usually frequency converters and <a href=\"https:\/\/inteq.lt\/en\/product-category\/pramones-automatika\/maitinimo-blokai\/\">power supplies<\/a>.<\/p>\n<h2>Step 2. Permissible temperature difference \u0394T<\/h2>\n<p>\u0394T = maximum permissible temperature inside the cabinet \u2212 maximum ambient temperature. For example, if the inside must not exceed 35 \u00b0C and the workshop reaches up to 25 \u00b0C in summer, \u0394T = 10 K.<\/p>\n<p>Important: a fan only cools with ambient air. If the surrounding air is as warm as or warmer than the permissible temperature inside the cabinet, ventilation will not help \u2013 you need a heat exchanger or an air conditioner.<\/p>\n<h2>Step 3. Airflow formula<\/h2>\n<p>Formula used by Rittal and other manufacturers:<\/p>\n<p><strong>V = f \u00d7 P \u00f7 \u0394T<\/strong><\/p>\n<ul>\n<li><strong>V<\/strong> \u2013 required airflow, m\u00b3\/h;<\/li>\n<li><strong>P<\/strong> \u2013 heat losses in the cabinet, W;<\/li>\n<li><strong>\u0394T<\/strong> \u2013 permissible temperature difference, K;<\/li>\n<li><strong>f<\/strong> \u2013 air property coefficient depending on altitude above sea level.<\/li>\n<\/ul>\n<table>\n<thead>\n<tr>\n<th>Altitude above sea level<\/th>\n<th>f, m\u00b3\u00b7K\/(W\u00b7h)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>0\u2013100 m<\/td>\n<td>3,1<\/td>\n<\/tr>\n<tr>\n<td>100\u2013250 m<\/td>\n<td>3,2<\/td>\n<\/tr>\n<tr>\n<td>250\u2013500 m<\/td>\n<td>3,3<\/td>\n<\/tr>\n<tr>\n<td>500\u2013750 m<\/td>\n<td>3,4<\/td>\n<\/tr>\n<tr>\n<td>750\u20131000 m<\/td>\n<td>3,5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>In Lithuania, f = 3.1\u20133.2 is sufficient almost everywhere.<\/p>\n<p><strong>Example:<\/strong> in the cabinet a frequency converter and power supplies, 400 W of losses in total, \u0394T = 10 K, f = 3.1. V = 3.1 \u00d7 400 \u00f7 10 = <strong>124 m\u00b3\/h<\/strong>.<\/p>\n<h2>Refinement: heat through the cabinet walls<\/h2>\n<p>When the cabinet is warmer than the surroundings, part of the heat escapes through the walls. It can be estimated with the formula <strong>Q = k \u00d7 A \u00d7 \u0394T<\/strong>, where k is the heat transfer coefficient (about 5.5 W\/m\u00b2K for a painted steel sheet) and A is the free surface area (not against a wall or another cabinet) in m\u00b2.<\/p>\n<p>Continuing the example: if the free surface is 1.5 m\u00b2, about 5.5 \u00d7 1.5 \u00d7 10 \u2248 83 W escapes through the walls. The fan then has to handle 400 \u2212 83 = 317 W, and V = 3.1 \u00d7 317 \u00f7 10 \u2248 <strong>98 m\u00b3\/h<\/strong>. If in doubt, calculate without the walls \u2013 you will get a safety margin.<\/p>\n<h2>Step 4. Filters reduce airflow \u2013 choose with a margin<\/h2>\n<p>A fan's catalogue airflow is often stated for free blowing. With an intake filter, an outlet grille and a clogged filter mat, the actual airflow is lower. Manufacturers' datasheets state airflows \"with outlet filter\" \u2013 select based on these and keep a margin. For the 98\u2013124 m\u00b3\/h example, it is worth looking at a ~250 m\u00b3\/h model, e.g., <a href=\"https:\/\/inteq.lt\/en\/product\/finder-7f-20-8-230-4250\/\">Finder 7F.20.8.230.4250 (230 V AC, 250 m\u00b3\/h, opening 224 mm)<\/a>, or at two smaller ones.<\/p>\n<h2>Fans with filter by airflow<\/h2>\n<table>\n<thead>\n<tr>\n<th>Airflow<\/th>\n<th>Opening<\/th>\n<th>Example in the catalogue<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>24 m\u00b3\/h<\/td>\n<td>92\u00d792 mm<\/td>\n<td><a href=\"https:\/\/inteq.lt\/en\/product\/finder-7f-20-8-230-1020\/\">Finder 7F.20.8.230.1020, 230 V AC<\/a> or <a href=\"https:\/\/inteq.lt\/en\/product\/finder-7f-20-9-024-1020\/\">7F.20.9.024.1020, 24 V DC<\/a><\/td>\n<\/tr>\n<tr>\n<td>55 m\u00b3\/h<\/td>\n<td>125\u00d7125 mm<\/td>\n<td><a href=\"https:\/\/inteq.lt\/en\/product\/finder-7f-20-8-230-2055\/\">Finder 7F.20.8.230.2055, 230 V AC<\/a><\/td>\n<\/tr>\n<tr>\n<td>85 m\u00b3\/h<\/td>\n<td>\u2013<\/td>\n<td><a href=\"https:\/\/inteq.lt\/en\/product\/schneider-electric-nsycvf85m230pf\/\">Schneider ClimaSys NSYCVF85M230PF, 230 V AC<\/a><\/td>\n<\/tr>\n<tr>\n<td>100 m\u00b3\/h<\/td>\n<td>177\u00d7177 mm<\/td>\n<td><a href=\"https:\/\/inteq.lt\/en\/product\/finder-7f-20-8-230-3100\/\">Finder 7F.20.8.230.3100, 230 V AC<\/a><\/td>\n<\/tr>\n<tr>\n<td>250 m\u00b3\/h<\/td>\n<td>224\u00d7224 mm<\/td>\n<td><a href=\"https:\/\/inteq.lt\/en\/product\/finder-7f-20-8-230-4250\/\">Finder 7F.20.8.230.4250, 230 V AC<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Each fan also needs an outlet filter (grille) of the same opening size, e.g., <a href=\"https:\/\/inteq.lt\/en\/product\/finder-7f-02-0-000-2000\/\">Finder 7F.02.0.000.2000 (125 mm)<\/a> ar <a href=\"https:\/\/inteq.lt\/en\/product\/finder-7f-02-0-000-4000\/\">Finder 7F.02.0.000.4000 (224 mm)<\/a>.<\/p>\n<h2>Installation and control<\/h2>\n<ul>\n<li><strong>Location.<\/strong> The fan is usually mounted at the bottom of the cabinet and blows cool air inside, while the outlet filter sits at the top on the opposite side. Warm air rises, so the airflow passes through the whole cabinet. It is important that the air does not take a \"short path\" past the equipment.<\/li>\n<li><strong>Thermostat.<\/strong> To stop the fan running unnecessarily and the filter clogging faster, connect it via a thermostat with an NO contact (switches on as temperature rises), e.g., <a href=\"https:\/\/inteq.lt\/en\/product\/finder-7t-81-0-000-2303\/\">Finder 7T.81.0.000.2303 (0\u202660 \u00b0C)<\/a>. Thermostats with an NC contact are used to control heaters.<\/li>\n<li><strong>Filter mats<\/strong> replace regularly \u2013 a clogged filter greatly reduces airflow. Replacement mats: <a href=\"https:\/\/inteq.lt\/en\/product\/filtras-schneider-electric-nsycaf125\/\">Schneider NSYCAF125<\/a>, <a href=\"https:\/\/inteq.lt\/en\/product\/rittal-3172-100\/\">Rittal 3172.100<\/a>.<\/li>\n<li><strong>IP rating.<\/strong> Once the fan is installed, it also determines the cabinet's protection rating. Most fans with filters are rated IP54. For more, see the article on <a href=\"https:\/\/inteq.lt\/en\/ip-apsaugos-klases-ip20-ip54-ip65-ip67-ip69k\/\">IP protection ratings<\/a>.<\/li>\n<\/ul>\n<h2>How to find them on inteq.lt<\/h2>\n<ul>\n<li>Fans with filters, outlet grilles, thermostats and filter mats can be found in <a href=\"https:\/\/inteq.lt\/en\/product-category\/pramones-automatika\/ventiliatoriai\/\">fans<\/a> category.<\/li>\n<li>Replacing an old fan? Enter its code in <a href=\"https:\/\/inteq.lt\/en\/paieska-pagal-koda\/\">search by manufacturer's code<\/a> or upload a photo of the label \ud83d\udcf7 \u2013 we will match a equivalent by opening, voltage and airflow.<\/li>\n<li>Not sure what airflow you need? Send us your equipment list and cabinet dimensions via <a href=\"https:\/\/inteq.lt\/en\/kontaktai\/\">u\u017eklausos form\u0105<\/a> \u2013 we will help you calculate it.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>How to calculate airflow for an electrical cabinet fan: heat losses, temperature difference, formula V = f \u00d7 P \/ \u0394T, filters and thermostat.<\/p>","protected":false},"author":1,"featured_media":6335,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":""},"categories":[2493],"tags":[],"class_list":["post-6334","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-pramones-automatika"],"_links":{"self":[{"href":"https:\/\/inteq.lt\/en\/wp-json\/wp\/v2\/posts\/6334","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/inteq.lt\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/inteq.lt\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/inteq.lt\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/inteq.lt\/en\/wp-json\/wp\/v2\/comments?post=6334"}],"version-history":[{"count":1,"href":"https:\/\/inteq.lt\/en\/wp-json\/wp\/v2\/posts\/6334\/revisions"}],"predecessor-version":[{"id":6337,"href":"https:\/\/inteq.lt\/en\/wp-json\/wp\/v2\/posts\/6334\/revisions\/6337"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/inteq.lt\/en\/wp-json\/wp\/v2\/media\/6335"}],"wp:attachment":[{"href":"https:\/\/inteq.lt\/en\/wp-json\/wp\/v2\/media?parent=6334"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/inteq.lt\/en\/wp-json\/wp\/v2\/categories?post=6334"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/inteq.lt\/en\/wp-json\/wp\/v2\/tags?post=6334"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}